X-PAND Sensitive Analysis of Particulate Matter

Most convenient price/performance solution in the market for elemental analysis

  1. General Details

    The X-PAND analyzer can test for inorganic air pollutant species while supporting compliance with the US-EPA’s air quality regulation requirements. Along with the power to quantify the deposits of airborne particulates up to 60 elements, the X-PAND is fast, accurate, easy to use, and achieves low detection limits. With the ability to analyze filters “as received” without destruction and with no preparation or extraneous handling, the instrument ensure that the air filter sample can be preserved for future reference.

    The innovative X-PAND analyzer uses patented Wide Angle Geometry (WAG™) option to provide high x-ray flux, leading to optimal excitation of samples. Through the use of secondary targets with computer varied voltages and emission currents, the X-PAND provide monochromatic excitation energy, increased signal-to-noise ratio, superior sensitivity, selective excitation of elements of interest, and extremely low detection limits, due to the near absence of background radiation.

     

    Key Applications:

    Air Filter Samples

  2. Technical Info
    • Non-destructive elemental analysis C(6)-Fm(100) from PPM to 100% concentrations.
    • Six customizable filters for fast and accurate determination of trace and minor elements.
    • Down to 125eV resolution.
    • Robust design, compact geometry.
    • Sample tray with 8/16 positions.
    • Easy to operate thanks to the proprietary nEXt™ software package.
  3. Standards

    Mining & Geochemistry

    • Iron, uranium
    • Coal, diamonds, limestone
    • Oil shale, rock salt and potash
    • Precious metals – gold (Au), silver (Ag),
    • platinum (Pt), palladium (Pd)
    • Rare earth elements
    • Cassiterite, cadmium and antimony, Cd, Sb
    • Light elements, such as C, N, f, Na, Mg, Al, Si, P,
    • S and Cl

    Metals & Alloys

    • Alloy Analysis
    • Precious Metals
    • Ores, Slags, Feeds, Concentrates, and Tailings
    • Silicon Metal
    • Metal Foil Thickness

    Petrochemistry

    • ASTM D7212, D7220, D7039, D7751, D5453 and ISO
    • 8754, 13032, 20846, 20884, 13032, 20847, IP531
    • ASTM D4294 (sulfur analysis)
    • Monitoring of Mo, Ba, Mn
    • ASTM D6481 (unused lubricating oils): Ca, P, Zn, S
    • Monitoring of wear metals: Sb, Sn, Mo, Ti, Ni, Cd,
    • Fe, V, Pb, Cr, Cu
    • Analysis of P, S, Ca & Zn in Lube Oil

    Used Oil

    • ASTM 6481 – Additives in New Lube Oils
    • ASTM 7751 – Additives and contaminants in new and used oils
    • IP 501 – EDXRF equivalence performance

    Cosmetics

    • Titanium and Zinc in Sunscreen
    • Iron, Titanium, and Zinc in Base Makeup
    • Metal Dyes in Cosmetics
  4. Documents
  5. Related Products